Cardinal 738 Indicator Manual
Appendix 111 10.7.2 Cardinal 738 Indicator Sample string for the Cardinal 738 indicator: String recognized by the 920i: Identifier 920i Stream Format Carriage Return Cardinal uses + for positive and – for negative, so the stream polarity tokens need to reflect this. The serial commands for the 920i are STR.POS#p=+ and STR.NEG#p=–. The identifier that the 920i recognizes indicates six digits of weight with a decimal and leading zeroes, with the decimal sent at the end of the weight. Valid characters are W, w, G, g, T, t, N, or n (lower case indicates left justified). W indicates current weight, G–gross weight, N–net weight, T–tare weight. /P, /S, and /T can be used to specify primary, secondary, or tertiary units. Minus (–) indicates sign inclusion; (0) indicates leading zeros.
Any terms or designations used in this manual are used as generalizations unless otherwise noted. Cardinal Scale Manufacturing Company in no way claims rights to or obligations from Cardinal Scale Manufacturing Company in no way claims rights to or obligations from.
- Free download or read online to books cardinal 738 manual at our complete and best. Free download cardinal 738 indicator manual pdf pdf manuals library.
- This manual was reviewed at the time of approval for publication. 5.1 PLACING THE INDICATOR INTO CALIBRATION MODE. 14 Cardinal 738.
First digit indicates field width in characters; a decimal point (.) indicates floating decimal point. A decimal with subsequent digit indicates fixed decimal with n digits to the right of the decimal. Two consecutive decimals (for example, ) send the decimal point even if it falls at the end of the transmitted weight field. There are four possible tokens for status bits that can be used: motion, out-of-range, valid, and invalid.
Cardinal 738 Indicator Manual
In the Cardinal, m indicates motion, o indicates out-of-range; a space is used for valid or invalid weights. The commands to set these tokens in the 920i are STR.MOTION# p=m, STR.RANGE# p=o, STR.OK# p=, STR.INVALID# p=. NOTE: A space must be entered following the equals sign on the OK and INVALID serial commands.

Bennett Trim Tab Indicator Manual

Space The Cardinal uses two-character, lower-case units identifiers. The commands to set these tokens in the 920i include: STR.PRI# p=lb (options: kg, g, tn, t, gr, oz, or sp), STR.SEC# p=kg and STR.TER# p=kg (options: lb, g, tn, t, gr, oz, or sp). Space The mode used for Cardinal is g for gross and n for net.
These tokens are set using the STR.GROSS# p=g and STR.NET# p=n tokens. Space Space The end of line character is an ETX in this example, so the hex value of is entered in the string. Cardinal Sample String Identifiers.